Ossareh1352 (Structural) 27 Jul 08 8:17
Dear engineers

For your kind information , in our project 2 LPG pipe lines (C3 and C4) will be going through a city to Jetty. I need a standard to know the required space around these LPG lines which we do not have the athority to build any building as safety point of view. If you know any international standard in this regard please let me know.

best regards
   

dcasto (Chemical) 28 Jul 08 12:38
There is no international standard.  There isn't even on in the US.  I've seen cities that passed rules that all new houses must be 15' from the rights of way (ROW), which put our 2260 psi line 25' from a foundation.  That was better than what the house developer wanted, he was going to allow 10' of clearance. 字串9

Ossareh1352 (Structural) 15 Aug 08 6:08
dear dcasto

is it ok for underground pipeline or above ground. our pipeline is underground about 2 m. according to your experiance 15' is enough ? 25' is from the edge of foundation up to pipeline?

dcasto (Chemical) 16 Aug 08 2:05
I'd like 50', but I've lived with 10' from the ROW to a home, which was 15' from the pipeline .  The line had a 2180 psi MAOP.

To make up for small distance we had line markers on each fence in backyards and we went door to door annually.  the home owners tried to sue home builder and the home builder tried to sue me personally for interferance with his business.  Niether one won because of local laws and federal laws.  I threathened to put up cameras on our ROW because our signs were disappering, we knew it was the builder.

字串6



tdlai (Chemical) 9 Oct 08 23:26
Hi guys,

I would come up with a Risk Assessment and make a risk profile along the pipelines. Wherever risk level is lower than 10-6 then the development of building should be granted, according to UK HSE (UK Health & Safety Executive) for land use.

Many consultant such as DNV, Advantica etc can be contacted for this kind of issue.
  Process Engineer in Vietnam

(Click:

Previous:Alkylation acid header   Next:Energy Conservation
[Add TO Favorites] [TOP] [PRINT] [CLOCE WINDOWS]  
  Hot Article
·auto ignition temperature
·What is a flatolet?
·Material selection for higher
·ASTM D 1160 to TBP conversion
·High TAN Crudes
·what is "thermosyphon&quo
·Kinematic Viscosity and Densit
·Nelson complexity index
·Pyrophoric Iron sulfide
·Nelson Farrar refinery cost in
·Good refining literature
·Simulation softwares
  Related Articles
·Energy Conservation
·Cp/Cv for PSV calculation
·Reactor life prediction for Me
·Carbon Disulfide in Naphtha
·Sulphur degassing ejector flow
·Flash Point Index
·H2 Manufacturing unit HTS Reac
·Used lube oil quality evaluati
·crude oil approval process
·Cracked Naphtha-Light Cycle Oi
·Used oil refiners-....please
·Fluorine Contamination of Crud
Power by DedeCms