Petroleum Engineers

 
Home | Petroleum engineering other to | Petroleum exploration engineer | Petroleum refining engineering
  Position:HOME>Petroleum production engineeri>Article Content
Asphalt Storage
Source:Internet Author:Unknow Pubdate:2008-12-14  
jcmme (Mechanical) 13 Nov 08 18:30
Good Afternoon,

Does any one know about applicable design codes or standards for the design/fabrication of storage tanks for liquid asphalt?

Thanks,

europipe (Chemical) 17 Nov 08 6:25
I worked at an asphalt plant and they built tanks acc.
API620 or 650.
Calculate a steam coil for it and that's it.

Greetings

jcmme (Mechanical) 17 Nov 08 11:28
Thank you..

chemicalengineerthai (Chemical) 3 Dec 08 8:41
1) Steam condition should be MP steam ( 10 barg , 5 C superheated)

2) Heat tracing pressure drop  4 bar/KM.

3) hot insulation to tank required
字串1


4) Gaugehat 8" on the top, Level guage mechnatic type

5) Screw pump is applied

6) Tank max height 25 meter for economic purpose

(Click:

Previous:Maximum Pipe Deflection   Next:Downhole choke sizing and information
[Add TO Favorites] [TOP] [PRINT] [CLOCE WINDOWS]  
  Hot Article
·Hall Yarborough paper
·Dropped Object Study
·pump jack diagram
·slug catcher design
·two phase pressure drop
·PIPEPHASE
·Blow case sizing
·Choke modeling using OLGA
·Aniline Point Calculation
·GVF; GOR & GLR units?
·GVF vs GLR or GOR
·PSV & weep holes
  Related Articles
·Downhole choke sizing and info
·Compressor Controls
·Finding guiderail point of nee
·Minnesota Snow Load
·Product warranty
·Underwater Intake Structure
·Water Treatment
·PE Exam Preparation
·Concrete Ringwall Design for W
·Design (Technical) Specificati
·Catch basin design
·rebar
Power by DedeCms