samlukeben (Petroleum) 20 Jan 04 9:12
Hi,

I would like to conduct a quick “Straw Poll” of members involved in completion design as to the practical benefits of using “Flow Couplings” either side of a subsea safety valve. I understand the rationale behind their use in high velocity/turbulent flow areas of a completion, however, is it conclusive that they beneficial?

Your comments and justifications “for” and “against” would be very much appreciated….

PS I believe some operators are not using them any longer on platform wells in the UK sector.?

Definition:  Flow Coupling - n.  [Well Completions]    
A relatively short, heavy-walled completion component installed in areas where turbulence is anticipated. The additional wall thickness prevents early failures due to erosion in the turbulent flow area. Flow couplings are typically installed above and below completion components, such as landing nipples, that may affect the flow. 字串3




(Click:

Previous:ELECTRIC MOTOR SELECTION FOR A PCP PUMPS   Next:Vapor Measurement Suggestions
[Add TO Favorites] [TOP] [PRINT] [CLOCE WINDOWS]  
  Hot Article
·Hall Yarborough paper
·Dropped Object Study
·pump jack diagram
·slug catcher design
·two phase pressure drop
·PIPEPHASE
·Blow case sizing
·Choke modeling using OLGA
·Aniline Point Calculation
·GVF; GOR & GLR units?
·GVF vs GLR or GOR
·PSV & weep holes
  Related Articles
·Vapor Measurement Suggestions
·URGENT ENQUIRY
·induction generators driven by
·The NEW GM engine Hydraulic Po
·Nippon Steel Threads
·Lift Gas Response Curve Equat
·Lift Gas Response Curve Equat
·looking for production optimiz
·SPILL OIL RECOVERY
·H0 fire barriers
·Formation damage
·Jack up Rig move & platfor
Power by DedeCms